| Specification | P55 | P300A/D | PS309 | P365D | P532A/D | DR800 | P2 Series | |
| TYPE | Differential, Gage, or Absolute Compact Transducer | Differential, Gage, or Absolute Strain Gage Replacement | Differential, Gage or Absolute Digital Display Pressure Manometer | High Line Differential Tansducer | Differential, Gage or Absolute 2 or 4 Wire Transmitter | Draft Range Differential Transmitter | General Purpose Gage Pressure Transmitter | |
| FULL SCALE RANGES | P55D: ±0.08 to 3200 psid P55A: 0.08 to 3200 psia | ±0.08 to 3200 psid 0.08 to 3200 psia | ±0.08 to 3200 psid 0.08 to 3200 psia | P365D: ±5 to ±10,000 psid | ±0.1"H2O to ±3200 psid 0.08 to 3200 psia | ±0.25" to ±100" H2O 2.5:1 Turndown | 15 psig & above | |
| AVAILABLE RANGES (See Pressure Range Chart) | -20 THRU -64 | -20 THRU -64 | -20 THRU -64 | P365D: -38 THRU -70 | P532A: -20 THRU -64 P532D: -06 THRU -64 | See Ordering Information | As above | |
| ACCURACY(1) | P55D: ±0.25% FS(6) | ±0.25% FS(6) | ±0.25% FS(6) | ±0.5% (5) | ±0.25% FS(6) | ±0.5% | 0.25% | |
| MATERIAL | 410SST, 17-7 PH SST(2) | 410SST, 17-7 PH SST(2) | 410SST(4), 17-7 PH SST(2) | 410SST(4) | 410SST(4) | 410SST | 17-7 PH SST | |
| OVER PRESSURE MAXIMUM 0.5% OUTPUT SHIFT | P55D: 200%(7) P55A: 20 psia or 200% (4000 psi Maximum) | P300D: 200%(7) P300A: 20 psia or 200% (4000 psi Maximum) | PS309D: 200%FS(7) PS309A: 20 psia or 200%FS (4000 psi Maximum) | 200% FS to 12,500 psi Maximum | P532D: 200%FS P532A: 20 psia or 200% FS (4000 psi Maximum) | ±5psid | 200% FS ≤3000 psig 150%FS>3000 psig | |
| MAXIMUM LINE PRESSURE & ERROR | 3200 psig <1% FS/1000 psig | 3200 psig <1% FS/1000 psig | 3200 psig <1% FS/1000 psig | 12500 psig <1% FS/1000 psig, 3% Max. | 100 psig (ranges ≤2"H2O)(9) other ranges 3200 psig | 100 psig <1% FS/100 psi | N/A | |
| TEMPERATURE ERROR(3) | ±0.5% FS/100F - Standard ±0.75% FS/100F - Extended | <2% FS/100ºF | <2% FS/100ºF | 1% FS | 2% FS/100ºF | <3% FS/100ºF | 1.5% FS/100ºF | |
| PRESSURE PORTS(4) | P55D: 1/8-27 NPTF P55A: 5/16-24 UNF-2B & 1/8-27 NPTM adapter | P300D: 1/8-27 NPTF P300A: 5/16-24 UNF-2B & 1/8-27 NPTM adapter | 1/4" O.D X 5/8" Long Brass Tube | 5/16-24 UNF - 3B 8-32 Bleed Screw | 1/4 - 18 NPTF on 21/8" centers | 1/4-18 NPT with 1/2-14 NPT Adapter 21/8" centers | 1/4-18 NPT male 7/16-20 UNF to SAE J-514 Male 1/8-27 NPT male | |
| APPROXIMATE WEIGHT APPROXIMATE SIZE | 16 ounces 41/2" X 11/2" X 1 1/2" | 16 ounces 41/2" X 11/2" X 1 3/4" | 35 ounces 71/4" X 43/4" X 1 3/4" | 16 ounces 41/2" X 13/4" X 1 1/2" | 8 lb 41/4" X 71/4" X 7 1/4" | 16 lb 10" X 51/2" X 4 1/2" | 3.5 ounces 1.4" X 4" | |
| POWER REQUIRED | 9-55 Vdc @3.0 mA(4) | 5-12 Vdc @4.0 mA | Six 1.5 Vdc AA Batteries(4) or External Power Supply | 9-55 Vdc @3.0 mA(4) | 14-40 Vdc or 115/230 VAC(4) | 12-45 Vdc | 24 Vdc Nominal | |
| OUTPUT SIGNAL REGULATION FREQUENCY RESPONSE | 4-20 mA, ±5Vdc (4) <0.02% 250 Hz | ±5mV/V Ratiometric 200Hz | ±2Vdc (4) N/A 15.9Hz(4) | 4-20 mA, ±5Vdc (4) <0.02% 250 Hz | 4-20 mA (4) <0.01%FS/V 20 Hz | 4-20 mA <0.01%FS/V Time Constant: 1/4 to 8 Sec | 4-20 mA, 0-5Vdc, Others <0.01% FS/V | |
| LIT BY FAX CODE# | 2550 | 2551 | 2552 | 2553 | 2555 | 2556 | 2557 | |
| Notes: | (1) Accuracy includes non-linearity, hysteresis, and non-repeatability (RSS). | (4) Additional options available. | (7) Differential sensors have maximum overpressure of 200% FS, but not exceeding 4,000 psig. | |||||
| (2) 17-7 ph SST material available only for ranges above 8psi (-40 on the Pressure Range Chart). | (5) P365D ±1.0% over 5,000 psi. | Absolute sensors have an overpressure of 20psia or 200% FS, whichever is greater, but not exceeding 4,000 psig. | ||||||
| (3) Temperature error includes non-linearity and hysteresis. | (6) Accuracy for absoute models is ±0.5%. | |||||||
| (9) Maximum line pressure for DP transmitters with ranges ≤2.25" H2O must not exceed 100psig, and the maximum line pressure error is <1% FS. | ||||||||
| For DP Transducers with ranges>2.25"H2O the maximum line pressure is 3200 psig and the line pressure error is <1% FS/1000 psig. | ||||||||